ID: 9119552
Spectrometer
P/N: L6020036
Lambda 950 STD Detector Assy
Polarizer Assy-L900
Software: (UV Winlab 5.2.0 / Accessory software UV Winlab V1.1.3 / Software utilities Ver 7.00)
Bandwidth:
0.05 nm - 5.00 nm in 0.01 nm increments UV/Vis range
0.20 nm - 20.00 nm in 0.04 nm increments NIR range
Fixed resolution, constant energy or slit programming
Light Source: Pre-aligned tungsten-halogen and deuterium
Optics: Split Beam
Photodetector: photomultiplier
Photometric Range UV/Vis: 8 A NIR: 6 A
Wavelength Range: 175 to 900 nm N2 purge required below 185 nm
Power Requirements: 90 VAC - 250 VAC, 50/60 Hz; 250 VA
Beam Splitting System: Chopper (46+ Hz, Cycle: Dark/Sample/ Dark/Reference, Chopper Segment Signal Correction)
UV/Vis resolution: 2 A
At 220 nm, 10 g/l NaI ASTM method: At 340 nm, 50 mg/l NaNO2 ASTM method: At 370 nm, 50 mg/l NaNO2 ASTM method: At 1420 nm, H20 1 cm path length: At 2365 nm, CHCl3 1 cm path length:
Wavelength accuracy:
UV/Vis: ± 0.080 nm
NIR: ± 0.300 nm
Wavelength reproducibility:
UV/Vis (Deuterium lamp lines)
NIR (Deuterium lamp lines)
Standard deviation of 10 measurements UV/Vis
Standard deviation of 10 measurements NIR
Photometric accuracy:
Double Aperture Method 1 A: ± 0.0006 A
Double Aperture Method 0.5 A; ± 0.0003 A
NIST 1930D Filters 2 A: ± 0.0030 A
NIST 930D Filters 1 A: ± 0.0030 A
NIST 930D Filters 0.5 A: ± 0.0020 A
K2Cr2O7-Solution USP/DAP method: ± 0.0080 A
Photometric linearity:
Addition of filters UV/Vis at 546.1 nm, 2 nm slit, 1 second integration time
At 1.0 A: ± 0.0060 A
At 2.0 A: ± 0.0160 A
At 3.0 A: ± 0.0050 A
Photometric reproducibility
Standard deviation for 10 measurements, 2 nm slit, 1 second integration time 1 A with NIST 930D Filter at 546.1 nm: = 0.00016 A
0.5 A with NIST 930D Filter at 546.1 nm: = 0.00008 A
0.3 A with NIST 930D Filter at 546.1 nm: = 0.00008 A
Photometric display: Unlimited
Photometric stability:
After warm-up at 500 nm, 0 A, 2 nm slit, 2 second integration time, peak to peak: = 0.0002 A/h
Baseline flatness:
190 nm - 3100 nm, 2 nm slit 0.20 second integration time UV/Vis, no smoothing applied 0.24 second integration time NIR, no smoothing applied: ± 0.0008 A
Purging:
Optics: Yes
Sample compartment: Yes
Light beam:
90 mm above the base plate
120 mm beam separation
3 mm - 12 mm beam height.
PERKIN ELMER Lambda 950は、研究、品質分析、生産管理における正確な紫外線(UV-Vis)測定を提供する高精度の分光光度計です。幅広いアプリケーションに優れた性能を提供し、分光解析の最も要求の厳しい要件を満たすための電力と柔軟性を提供します。ラムダ950は、大口径の光学部品を備えた回折格子光学系で構成されており、利用可能な最高レベルの感度とスペクトル分解能を提供します。これにより、定性的および定量的なアプリケーションの両方に必要な正確な情報を提供することができます。これは、190〜950ナノメートル(nm)の間で測定することができ、最大16波長ポイントのフルスペクトラムスキャン、または2波長ポイントの高速測定が可能です。直感的で使いやすいインターフェイスを備えており、PCまたはラップトップに直接接続することで、使いやすく構成が簡単です。ソフトウェア制御オプションにより、迅速かつ正確な校正とデータ取得が可能です。サンプルアライメントを自動化し、高精度・高精度を実現します。自動スリットサイズ選択機能により、最大分解能を実現し、測定精度をさらに向上させます。PERKIN ELMER Lambda 950には、リモートアクセス用の内蔵光ファイバー、正確な時間ベース測定用の露出タイマー、安定した読み取りのための温度制御エンクロージャなど、多くの追加機能があります。その先進的な光学系、高感度、高解像度により、この分光光度計は実験室で可能な限り最高の性能を提供します。