中古 WATKINS-JOHNSON 1000H #199252 を販売中
この商品は既に販売済みのようです。下記の同じようなプロダクトを点検するか、または私達に連絡すれば私達のベテランのチームはあなたのためのそれを見つけます。
タップしてズーム
販売された
ID: 199252
Reactor / Hydride system, 8"
3.0 system with exhaust modified to 2.0 inch for better uniformity
Silane (SiH4) based SiO2
Tool was devoted to SiO2 only; Never ran dopants
Voltage: 208, 50/60hz, 3 phase
(2) Sets of parallel plate injectors
Planned processes:
Film type: NSG, Chamber 1: 380°C deposition temp., 250A thickness, 8", 11ipm belt speed
Film type: NSG, Chamber 4: 380°C deposition temp., 2000A thickness, 8", 11ipm belt speed
Film type: NSG, Chamber 4: 380°C deposition temp., 1000A thickness, 8", 11ipm belt speed
Gas box:
(4) D1N2, 10slm, Lintech MC-200B, 100% concentration
(4) O2, 1.5slm, Lintech MC-2100O, 100% concentration
(4) Sep N2, 20slm, Lintech MC-200B, 100% concentration
(4) B2H6
(4) PH3
(4) SiH4, 0.2slm, Lintech MC-2100MO, 20% concentration, N2 balance gas
(4) D2N2, 6slm, Lintech MC-200B, 100% concentration
Cable lengths:
UPS Communication Cable (Note 1) 40ft, Part No: 815003-378
Communication Cable (Note 2) 20ft, Part No: 815001-732
Reactor Facility Cable 40ft, Part No: 907233-004
UPS Power Cable 10 40ft, Part No: 985227-004
UPS Extension Cable 30ft, Part No: 907202-003
Exhaust modifications done at time of original build:
3.0 to 2.0 Exhaust Downgrade Kit:
A) (8) Adaptor Assy, 3.0 to 2.0 Orifice
B) Toroidal 3.0 to 2.0 orifice installation kit (replaces 912010-001)
C) Process output plumbing kit (replaces 912106-001)
D) Hoist Adaptor Kit
E) 2.0 Muffle Etch Hardware:
3 color signal tower: Green-Yellow-Red
SECS II SW option
English software
Modifications by OEM:
1 - The 3" exhaust was modified at the torrodial orifices to 2" that can provide better on wafer uniformity for the SiO2 film
The torrodials, bellows, and injector vents also have 2" exhaust type
Downstream of the torrodials to the house exhaust the system is the standard 3" type
2 - Gas box has SiH4, N2, and O2 MFC's, but never had dopant (B2H6 and PH3) MFC's installed for BPSG films
This tool has never run dopants
There are SS tube spools in place where the dopant MFC's would normally be placed
If the buyer wants to run doped films that is no problem, they just need to add the MFC's into the tool
The original owner only used the tools for various SiO2 films and wanted to keep them (and the system) as pure and dopant free as possible
UPS may not be included/or non-functional due to age
Tool is de-installed, barrier bagged, and crated
Currently stored in a warehouse
1996 vintage.
WATKINS-JOHNSON 1000Hは、詳細な核物理学実験を実行するために設計された高度な研究グレードの原子炉です。CNR (Compact High Neutron Flux Reactor)は、原子核反応をシミュレートし、放射線量を測定するために研究室で一般的に使用される。原子炉は、非常に高い中性子束を生成することができるので、実験室、大学、発電所にとって理想的なツールです。これは、信頼性の高い安全性能を可能にする特許技術の範囲とともに、統合された安全システムを誇っています。1000Hは、中央原子炉心、サラウンドシールド、グラファイトリフレクター、モデレーター、プレナムチャンバーで構成されています。原子炉心は、核反応を起こすために高度に濃縮されたウランで満たされています。グラファイト反射器とモデレータは中性子フラックスを制御し、反応範囲を制限します。プレナムチャンバーは、冷却液の流入と流出を可能にします。原子炉は、スケジュールされたメンテナンスを必要とせずに長期間稼動することができます。WATKINS-JOHNSON 1000H原子炉の統合安全システムは、原子炉の性能と異常を監視するように設計されています。これは、中性子フラックス、臨界性、および放射線レベルに関するデータを記録および記録する多数のセンサーと検出器を備えています。さらに、原子炉には緊急停止システムが装備されており、安全でない状況が発生した場合には直ちに原子炉を停止するように設計されています。1000H原子炉の最大出力は1,000ワットです。小型で簡単にアクセスでき、高度に規制された環境で信頼性の高いパフォーマンスとデータを提供します。原子炉は核物理学者の間で人気のあるツールであり、中性子フラックスの決定、断面測定、放射化学的解析など、さまざまな有用な機能を提供しています。WATKINS-JOHNSON 1000H炉は、堅牢で高度で信頼性の高い研究ツールです。
まだレビューはありません