中古 HUETTINGER TruPlasma RF 1003 #9114482 を販売中
URL がコピーされました!
ID: 9114482
High frequency power supply
13.56 MHz
RF Output:
Full rated power into 50 Ohm 3000 W
Nominal power range 10 - 3000 W
Selectable power range 1 - 3000 W
Output power (incident) at VSWR 1.1: 1 100 % of full rated power
Output power (incident) at VSWR 1.5: 1 95 % of full rated power
Output power (incident) at VSWR 2: 1 66 % of full rated power
Output power (incident) at VSWR 3: 1 50 % of full rated power
Output power (incident) at infinite VSWR >= 20 % of full rated power
Reflected power limit 600 W
Operating frequency 13.56 MHz ± 0.005 %
Nominal load impedance 50 Ohm
Harmonic signals at full rated output power into 50 Ohm non-reactive load: < -40 dBc
Spurious signals at full rated output power into 50 Ohm non-reactive load: < -50 dBc
Connector 7/16 female
RF Out accuracy CW for digital control:
Power measurement (Compatibility with other frequencies)
Power detection (Forward and reflected) <= -26 dB at frequencies above 27.0 MHz, <= -26 dB at frequencies below 7.0 MHz
Power accuracy into 50 Ohm (typ.) ± 0.8 W or ± 1 % of set point
Fluctuation (Short term stability within 60 s observation time) into 50 Ohm at 1000 W (typ.) ± 1 W
Drift (long term stability during continuous 30 minutes of operation) into 50 Ohm at 1000 W (typ.) ± 1 W
Power repeatability into 50 Ohm for same generator (typ.) ± 0.8 W or ± 0.8 % of set point
Power repeatability into 50 Ohm generator to generator (typ.) ± 0.8 W or ± 1 % of set point
Power rise time for 10 to 90 % of full power < 50 ms
Power rise time for delta 200 W < 10 ms
Turn off time (RF off) from 100 % to 1% of full power: 10 μs
Overshoot < 2 % of set point
Set point response time from end of command to 90 % of set point: < 100 ms, < 15 ms (typ.)
Boot time < 5 s
Relative phase shift (between clock input and RF output): 0 – 360°
Phase shift resolution 0.1°
Pulse frequency: 10 Hz to 50 kHz
Duty cycle: 1 to 99 %
Min. pulse on time: 10 μs
Min. pulse off time: 10 μs
Pulse rise time: < 1 μs
Pulse fall time: < 1 μs
Power overshoot: < 10 %
Power: 200 / 208 VAC ± 10 %, 3 Phase and ground, 50/60 Hz
Auto frequency tuning (13.56 MHz ±.05 %)
Arc management, Dnet
3kW, 13.56MHz
Ultra-wide mains 200-480VAC 3-Phase, 10Hz - 50 kHz Pulse mode
HN Connection, RS-232/RS-485.
HUETTINGER TruPlasma RF 1003は、プラズマ用途向けに設計された、信頼性の高い高性能な無線周波数電源です。高効率回路で設計されたこの電源は、最大1000Wの出力を提供できます。はんだ付け、プラスチック溶接、レーザーエッチングなどの用途に最適な電源です。TruPlasma RF 1003は、+/-0.1MHzの周波数精度で30MHzと10kHzの間で調整できる可変周波数電源です。高い入力電圧範囲の200-240VACを備えており、最大400Vまでのピーク入力電圧を受け入れることができます。この電源は、+/-10Vの優れた電圧レギュレーションと+/-2.5Aの電流レギュレーションを備えています。HUETTINGER TruPlasma RF 1003は、必要な正確な出力を得るのに役立つ調整可能なパワーレベルを備えた内蔵のデジタルディスプレイを備えています。ディジタルディスプレイは、電源を開けなくても簡単に周波数やその他の設定を調整することができます。TruPlasma RF 1003には、過電圧保護、過電流保護、過熱を開始した場合に直ちに電源を遮断するサーモスタットなど、多くの安全機能が組み込まれています。さらに、この電源は、負荷が変化しても出力電力を安定した状態に保つための動的負荷調整システムを利用しています。HUETTINGER TruPlasma RF 1003には、RS232、 RS485、 Profinetなどの多くのインターフェイスオプションが付属しています。これにより、電源の制御が強化され、アプリケーションに必要な出力が確実に得られるようになります。全体として、TruPlasma RF 1003は強力で信頼性の高い電源で、プラズマアプリケーションに最適です。高出力、可変周波数、優れた電圧および電流レギュレーション、安全機能、およびさまざまなインタフェースにより、これは信頼性の高い高品質のパフォーマンスを求める人々にとって理想的なソリューションです。
まだレビューはありません